H.T.H.'s metallic flexible pipes with parallel ondulation, without gaskets and seam, guarantee perfect tight of pressure and also very high flexibility, assured by the deformation of continuos section.
Our pipes are provided, in function of operating conditions, of one or more metallic braid, to resist to the bottom boost caused by internal pressure.
Our pipes are designed conformly ISO 10380.
Installation rulesMaterialsFlexible stainless austhenitic steel pipes
AISI 321
- ISO 683/13 Tipo 15
- ASTM A 240 Type 321
- DIN WN 1.4541
AISI 316 Ti
- ISO 683/13 Tipo 21
- DIN WN 1.4571
AISI 316 L
- ISO 683/13 Tipo 19
- ASTM A 240 Type 316 L
- DIN WN 1.4435
Metallic braid with stainless austhenitic steel
- AISI 304
- ISO 683/13 Tipo 11
- ASTM A 580 Type 304
- DIN WN 1.4301
On demand
- AISI 316 Ti
- ISO 683/13 Tipo 21
- DIN WN 1.4571
TemperatureFrom -270 °C to +600 °C.
Pressure
Pressure, shown ad "PE" on the tables, is the maximum operating pressure at ambiental temperature.
For higher temperature it must be conveniently reduce.
Double walled metallic flexibile pipes, series 100/dWithout braid 100/d-0, with 1 braid 100/d-1, with 2 braid 100/d-2
DN |
Internal diameter A |
External diameter B/C |
Static curvature radius R min. |
Dinamic curvature radius R.d. |
Maximum operating pressure** |
TIPO |
mm |
Inc. |
mm. |
mm. |
mm. |
mm. |
Bar |
20 |
3/4" |
22 |
27.5 29.3 31 |
30 |
80 |
4 64 100 |
100/d-0xxx.020 100/d-1xxx.020 100/d-2xxx.020 |
25 |
1" |
25.5 |
33.5 35 37 |
40 |
120 |
4 60 95 |
100/d-0xxx.025 100/d-1xxx.025 100/d-2xxx.025 |
32 |
11.4" |
34.2 |
42 44 46 |
50 |
150 |
3.5 50 83 |
100/d-0xxx.032 100/d-1xxx.032 100/d-2xxx.032 |
40 |
11.2" |
40.1 |
52 54 56 |
60 |
210 |
2.5 43 52 |
100/d-0xxx.040 100/d-1xxx.040 100/d-2xxx.040 |
50 |
2" |
50.4 |
64 66 70 |
70 |
320 |
2.5 40 50 |
100/d-0xxx.050 100/d-1xxx.050 100/d-2xx.050 |
65 |
21/2" |
65.4 |
81 84 87 |
78 |
360 |
2 30 38 |
100/d-0xxx.065 100/d-1xxx.065 100/d-2xxx.065 |
80 |
3" |
80.2 |
98 101.2 104 |
100 |
420 |
2 27 35 |
100/d-0xxx.080 100/d-1xxx.080 100/d-2xxx.080 |
100 |
4" |
100.2 |
120 123.2 126 |
120 |
500 |
2 20 32 |
100/d-0xxx.100 100/d-1xxx.100 100/d-2xxx.100 |
125 |
5" |
126.2 |
147 151.4 156.2 |
150 |
580 |
2 16 30 |
100/d-0xxx.125 100/d-1xxx.125 100/d-2xxx.125 |
150 |
6" |
149.8 |
174 178.4 182.1 |
200 |
690 |
1 13 22 |
100/d-0xxx.150 100/d-1xxx.150 100/d-2xxx.150 |
200 |
8" |
201.8 |
229 233.8 238 |
270 |
810 |
1 10 16 |
100/d-0xxx.200 100/d-1xxx.200 100/d-2xxx.200 |
** Maximum operating pressure at 20°C. Note: on specifying the pipes, substitute "xxx" with the kind of steel for the internal pipe: 321 or 316.
Installation rules